Sign In | Join Free | My burrillandco.com
Home > Copper Coil Water Cooler >

318V 3P 50HZ Copper Coil Water Cooler Tower Automatic Temperature Control

SHANGHAI YANYE INDUSTRIAL EQUIPMENT CO.,LTD
Contact Now
    Buy cheap 318V 3P 50HZ Copper Coil Water Cooler Tower Automatic Temperature Control from wholesalers
     
    Buy cheap 318V 3P 50HZ Copper Coil Water Cooler Tower Automatic Temperature Control from wholesalers
    • Buy cheap 318V 3P 50HZ Copper Coil Water Cooler Tower Automatic Temperature Control from wholesalers
    • Buy cheap 318V 3P 50HZ Copper Coil Water Cooler Tower Automatic Temperature Control from wholesalers
    • Buy cheap 318V 3P 50HZ Copper Coil Water Cooler Tower Automatic Temperature Control from wholesalers
    • Buy cheap 318V 3P 50HZ Copper Coil Water Cooler Tower Automatic Temperature Control from wholesalers

    318V 3P 50HZ Copper Coil Water Cooler Tower Automatic Temperature Control

    Ask Lasest Price
    Brand Name : YANYE /JIANGFAN
    Model Number : YCT/YKT/YNT/CLA/CLB/YKN
    Certification : ISO9001/CTI ON SITE
    Price : Negotiation
    Payment Terms : T/T
    Supply Ability : 350 set/ month
    Delivery Time : 70 days
    • Product Details
    • Company Profile

    318V 3P 50HZ Copper Coil Water Cooler Tower Automatic Temperature Control

    Copper Tube Cooling tower EVAPCO copper cooler T2 de-acidified 99.99% Cooling tower BAC copper tube cooling tower:


    2.2 Advantages for cooling towers

    1) Closed loop
    Preventing the impurities into the system to block the cooling tubes, soft water is adopted to avoid overheating caused by scaling to the water pipes.

    2) Automatic temperature control
    Automatic start/stop spraying system to achieve effective control on the temperature of cycled cooling water, the temperature of the cooling water can be controlled below 40 ℃. With this function, the water & energy cost is reduced to the lowest point with intelligent control to the number of working fans and start & stop of spray pump.

    3) No need of water pool and cooling tower
    Low cost, small space occupancy, easy installation and move with the welder.

    4) Automatic digital display of temperature control
    Energy efficient and user friendly.

    5) Cooling system structure
    Galvanized iron beam.

    6) High efficiency heat exchange
    Four side air inlet louvers supply sufficient amount of wind blowing through cooling coils taking most of the heat away, which effect is strengthened via spray cooling water running through the cooling coils.

    7) Small consumption of soft water
    Filling the soft water once is enough for half-year operation without water loss.

    Antifreeze is required in the winter season for areas subject to freeze temperature.

    1. Anti-freeze Solutions

    In the high-altitude area where temperature drops sharply during the winter season below 0℃, the circulation water of closed circuit cooling tower shall freeze without heat load even sometimes when the circulation water keeps running. Therefore, enough care shall be given to the anti-freeze measures for this concern. Normally two anti-freeze solutions are considered:
    (1) Put the circulation water under certain heat load, maintaining the water temperature higher than 7℃(for lower altitude area not higher than 3℃). To keep this heat load, normally the use of immersed electric heater is applicable, meanwhile a minimum flow rate of the circulation water shall be maintained.
    (2) The best solution is suggested the use of antifreeze liquid, like glycol. For detailed mixture proportions, please consult your WELL representative.

    • Glycol(C2H6O2)liquid is the main ingredient for most antifreeze mixtures, the negative aspect for this solution is largely its high cost (≈1000USD /Ton). Below is an reference mixture option:
    Glycol (wt%)01020304050588090100
    Congreal (C)-0.0-3.5-8-15-24-36-48-47-29-13
    • Alcohol(CH3OH or C2H5OH) provides a more affordable cost for application,while the following aspects must be considered:

    Methanol is poisonous, and enough care must be taken for safe operation

    Methanol and Ethanol is volatile, and after long term use, the density may decrease. Below 30% mixture ratio provides lowest volatile level and could be effective in the case of -20℃

    For external circulation that relates to spray system, certain measures shall be taken to avoid the spray water from getting frozen in the basin. Electrical immerse heater is recommended for this consideration.

    The spray pump also needs to be protected against cold weather, and this may concern the thermal materials like saw dust etc.

    Note: All chemical addictives must be compatible with the equipments and piping systems!

    Quality 318V 3P 50HZ Copper Coil Water Cooler Tower Automatic Temperature Control for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: SHANGHAI YANYE INDUSTRIAL EQUIPMENT CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)